Vibration Isolation of Auditorium with Floating Floors, Bournemouth Church
Mason UK installed the floating floor in the Auditorium for Watkin Jones on the Bournemouth Church Project. The Auditorium floating floor was 150mm thick and 775 square metres in area. The floor was poured in a single operation and jacked over 2 days to provide a 75mm air gap.
The Auditorium was designed for multi purpose use including Live Music, Film showings, Baptisms and many other applications.
Mason UK have also supplied several other products for this project in order to isolate the ceilings and walls.